EPEVER Photo voltaic Demand CONTROLLER Set up: TRACER AN Collection CONTROLLE
EPEVER Photo voltaic Demand CONTROLLER Set up: TRACER AN Collection CONTROLLE
Blog Article
The EPEVER Tracer AN Sequence Photo voltaic Demand Controller is actually a remarkably efficient solar controller made for off-grid solar techniques. Dependant on multiphase synchronous rectification technologies, it assures optimized Strength conversion and process steadiness for a variety of photovoltaic (PV) purposes.
Key Features in the EPEVER Tracer AN Sequence Controller
The Tracer AN sequence makes use of EPEVER Solar Demand Controller technologies for exceptional solar Electrical power harvesting. Important functions consist of:
Multiphase Synchronous Rectification (MSR) for improved Electricity conversion.
Innovative MPPT Algorithm with >ninety nine% effectiveness.
Twin-Phase Charging for Improved battery existence.
LCD Display with serious-time facts monitoring.
Multiple Load Management Modes like handbook and timer.
Complete Digital Protections versus overcharging, more than-discharging, brief circuits, and reverse polarity.
Step-by-Step Guide to Setting Up the EPEVER Tracer AN Collection Controller
one. Unboxing and Making ready the Controller
Assure all parts are incorporated: Tracer AN unit, temperature sensor, communication cables, and person handbook.
Confirm the design variety and voltage scores match your solar panel and battery specs.
two. Mounting the Demand Controller
Select a very well-ventilated, dry location near to the battery bank.
Secure the Tracer AN controller utilizing the presented mounting brackets.
Sustain appropriate clearance for heat dissipation.
three. Wiring the Photo voltaic Charge Controller
Caution: Normally observe correct security protocols and ensure the procedure is run off ahead of connecting elements.
Step one: Link the battery terminals towards the charge controller (positive to favourable, detrimental to detrimental).
Phase 2: Join the photo voltaic panel array towards the PV enter terminals.
Phase 3: Join the load terminals if utilizing a direct load relationship.
Phase 4: Double-Verify all connections for polarity and tightness.
4. Configuring the Controller visit here Settings
Electricity to the controller by connecting the battery 1st.
Use the LCD display to navigate the configurations menu.
Configure:
Battery Style: AGM, GEL, Flooded, Lithium.
Charging Parameters: Absorption voltage, float voltage.
Load Management Modes: Guide, timer, light-weight Command.
five. Monitoring and Facts Logging
The Tracer AN Series supports serious-time checking using the MT50 remote meter.
Data is often logged through the RS485 communication port applying application for instance Solar Station Computer system.
Remote checking is possible While using the EPEVER WiFi module.
6. Troubleshooting Popular Troubles
Problem one: No Energy Output
Test battery voltage and connections.
Verify PV panel voltage exceeds battery voltage.
Challenge 2: About-Voltage Safety
Validate the solar array’s voltage ranking.
Modify process parameters if essential.
Challenge 3: No Battery Charging
Inspect PV wiring for continuity.
Confirm MPPT options inside the menu.
Great things about the Tracer AN Sequence with MSR Technology
The multiphase synchronous rectification know-how makes sure:
Increased Efficiency: Lessened Power losses all through conversion.
Enhanced Dependability: Steady effectiveness below variable loads.
More time Battery Everyday living: Reliable and accurate charging profiles.
Conclusion
The EPEVER Solar Demand Controller with multiphase synchronous rectification technology can be an Fantastic option for optimizing solar power era and increasing battery lifestyle. By adhering to the above setup information, users can make certain utmost effectiveness and program longevity.